Practice 8 Bifen I T exam questions with instant feedback and cited explanations.
To achieve a 0.12% finished strength, how much product should be mixed with 49.75 gallons of water?
Answer: The mixing instructions state that 1 qt. of product in 49.75 gallons of water results in a 0.12% finished strength.
When treating for termites in soil, the label notes that the 0.06% rate should only be used in conjunction with what?
Answer: The notes for soil termite treatment state to use that rate only in conjunction with volume adjustments, foam applications or underground services applications.
What is the required dilution concentration for pre- and postconstruction applications against subterranean termites?
Answer: The label specifies a 0.12% dilution for pre- and postconstruction applications.
When treating soil for subterranean termites, what is the required application rate for a 0.06% dilution?
Answer: The label specifies 4 gallons of dilute dilution per 10 linear feet per foot of depth of the trench, or 1 gallon per 1.0 cubic feet of soil for soil treatments.
When performing pre- and postconstruction applications, what is the vertical application rate?
Answer: For pre- and postconstruction applications, the vertical rate is 2.0 gallons per 10 linear ft.
According to the label, how should subterranean termites in infested and/or damaged wood be treated?
Answer: The label states to treat infested/damaged wood in place using an injection technique described in the 'Control of Wood Infesting Insects' section.
For pre- and postconstruction applications using a 0.12% dilution, what is permitted regarding the volume?
Answer: The label states that for pre- and postconstruction applications, the volume of the 0.12% dilution may be reduced by 1/2 the labeled volume where desirable.
Which of the following is a stated restriction for using Bifen I T?
Answer: The label explicitly states: 'Do not apply at a lower dosage and/or concentration than specified'.